Filtration systems for desalination

I’mWATER designs and manufactures all types of water filtration systems for the industrial and municipal market.
Such as bed filters, cartridge filters, or disc filters, made of carbon steel and stainless steel, with epoxy, ceramic, or ebonite coatings, and ranging in diameter from 500 mm to 4 meters.
METALLIC AND FRP BED FILTERS
STANDARDIZED VERTICAL FILTER MODELS
| Model | D (mm) | Hc (mm) | Q (m3/h) |
|---|---|---|---|
| FV-1400 | 1400 | 1500-2000 | 12-20 |
| FV-1600 | 1600 | 1500-2000 | 16-26 |
| FV-1800 | 1800 | 1500-2000 | 20-33 |
| FV-2000 | 2000 | 1500-2000 | 25-41 |
| FV-2200 | 2200 | 1500-2000 | 30-50 |
| FV-2400 | 2400 | 1500-2000 | 36-59 |
D=Diameter. Hc = cylindrical height. Q = flow rate.
For filtration velocities of 8-13 m/h.
Many other sizes available upon request.
STANDARDIZED HORIZONTAL FILTER MODELS
| Model | D (mm) | Lc (mm) | Q (m3/h) |
|---|---|---|---|
| FH-1400-X | 1400 | 4000-12000 | Consultar según longitud |
| FH-1600-X | 1600 | 4000-12000 | Consultar según longitud |
| FH-1800-X | 1800 | 4000-12000 | Consultar según longitud |
| FH-2000-X | 2000 | 4000-12000 | Consultar según longitud |
| FH-2200-X | 2200 | 4000-12000 | Consultar según longitud |
| FH-2400-X | 2400 | 4000-12000 | Consultar según longitud |
D=Diameter. Lc = Cylindrical length. Q = Flow rate.
For filtration velocities of 8-13 m/h.
Many other sizes available upon request.
Internals and sight glasses
Lower distributors:
- Collector arms: suitable for water-only backwash – economical – good performance – recommended by default.
- Nozzle plate:
- Better distribution.
- Necessary for air and water backwash.
- Higher price.
Upper diffusers:
- FRP or Metal.
Sight glasses: highly recommended to verify the proper expansion of the media during backwash and ensure correct backwashing.
- Acrylic.
- Glass.

The filtration fronts are designed based on the customer’s flow rate and quality requirements. I’mWATER can provide guidance on system sizing.
The system can include a valve front, either manual or automated. The automatic valves can be motorized or pneumatic.
Valve boxes for pneumatic system control are also supplied, as well as air compressors if required.
The filtration and automatic backwash system is controlled by a PLC installed in the electrical panel of the facility.